contactusurl/sv-SE/waterinfrastructure/SearchInga resultatAnimation is not fully supported in Internet Explorer versionsitem founditems founditem foundsidoravSökVisarPå denna sidaYour Browser is outdatedÅterförsäljareDistributörOfficial DealerPremium PartneradresseradresserArticlesRegulatoriskt pressmeddelande,Regulatory press releases onlyEG. Food Hoses conformity evolution WebinarSelector Button
The Trelleborg LCR-S system is an essential method and cost-saving tool to repair and permanently seal main/lateral interfaces and connections from the main line (DN 135 - DN 600) down into the lateral (DN 100 - DN 200)
Smart tools to assist you
The exact determination of the damaged area and the correct positioning of the packer is the precondition for a successful installation.
The packer is therefore equipped with a camera, a telescopic wheel system and a rotary drive for utmost maneuverability and orientation in the pipe.
A special designed lifting mechanism, called "pathfinder", supports the correct positioning inside the sewer pipe at the damaged lateral connection.
Absolute process control
The monitoring camera installed on the packer assists in the positioning process.
Once the LCR-S packer has reached the junction, the mouth piece of the LCR-S hat profile or LCR-S liner can be turned by means of the push rod reel system for proper alignment with the branch.
You can monitor and control all operations with the external control unit.
Save installation through control mechanisms
The control mechanisms built into the system ensure the highest possible level of security and a high quality result:
Starting the inflation process is possible only after the lateral hose is locked in place.
When the lateral packer hose has been completely inverted, a clear acoustic signal is given to indicate that the inversion process successfully is finalized.
Curing at ambient temperatures
The resin systems used in the LCR-S process are ambient curing - this means that you do not need additional technical equipment for heat supply.
Long processing and short curing times increase safety of working and lead to better results. In addition, they are environmentally friendly and styrene-free. In combination with the glass-fiber reinforced carrier material, you will achieve excellent mechanical properties and a sustainable rehabilitation result.
Diameters & Angles
Main Pipe Diameters
DN 100 - DN 600 | 4" - 24"
Lateral Pipe diameters
DN 100 - DN 200 | 4" - 8"
Connection Angles
30° to 90°
Pipe Material
The method repairs circular pipes of
asbestos cement
cast iron
concrete
plastics (HDPE, PVC, GRP)
reinforced concrete
vitrified clay
Applicable Damages
Leaks with or without groundwater infiltration or exfiltration at pipe joints, pipe walls, junctions, transitions, etc.
Displaced pipes, cracks and debris, ruptures
Mechanical wear
Corrosion
Limitations
extreme pipe or joint offsets
broken or collapsed pipes
large cross-sectional reductions in conjunction with bedding problems
longitudinal cracks at pipe connections
Training on theory and practice
Good practice-oriented training of our installers is a major concern for us and a component of our quality management approach.
Only qualified professionals with training are permitted to use our systems. Qualified personnel will be issued with a training certificate by Trelleborg Pipe Seals.
Related products/information
Additional technical Equipment, Consumables, Support