Forsheda 607 PIP-Lock, Sealing System for Sewer and Stormwater Pipes, Indoor Irrigation UndergrounWater

Size Examples

Examples of Sizes 

PIPE SIZE A B

6

0.40 0.96
8 0.44 1.06
10 0.54 1.28
Please conctact Trelleborg Pipe Seals for technical advice and joint design recommendations to meet your performance requirements
Forsheda 601 Power-Lock. Trelleborg

Dimensions, inches


Subject to change for technical reasons

Joint Assembly

F576 Angerlock. Trelleborg

Step 1

The spigot and socket of the pipe should be checked for damage prior to jointing. 

The pipe spigot should be chamfered with an angle of 15°, taking care to remove all burrs. 

Both spigot and socket including the sealing ring should be free from dirt and other foreign matter. 

Lubricant should be applied evenly to the spigot end of the pipe.


Forsheda 601 Power-Lock. Trelleborg

Step 2

Immediately after lubrication, the spigot should be brought into contact with the socket.

Both spigot and socket should correctly aligned and then slide the spigot into the socket, thus compressing the seal until the joint is fully made.